Text from PDF Page: 056

Section 25 CYCLE TESTING OF 1.7kWh BATTERY SYSTEM INTRODUCTION The cycling objectives for the 1.7kWh system are to: • determine the electrochemical life of the electrodes • verify the adequacy of the electrode to bus contact ® cycle system continuously in a controlled test regime • collect data to fully characterize system In April of 1976, the 1.7kWh system was first cycled. A detailed description of the results was published in an earlier report (25-1). A delivery of 1.7kWh with an average electrochemical energy efficiency of 64% was recorded for the 54 cycles acquired during 1976. Figure 25-1. Photograph of 1.7kWh Battery System Installed in Laboratory Hood 25-1

PDF Image | Development of the Zinc-Chlorine Battery for Utility

development-zinc-chlorine-battery-utility-056

PDF Search Title:

Development of the Zinc-Chlorine Battery for Utility

Original File Name Searched:

6302789.pdf

DIY PDF Search: Google It | Yahoo | Bing

Salgenx Redox Flow Battery Technology: Power up your energy storage game with Salgenx Salt Water Battery. With its advanced technology, the flow battery provides reliable, scalable, and sustainable energy storage for utility-scale projects. Upgrade to a Salgenx flow battery today and take control of your energy future.