Text from PDF Page: 222

Table 37-7 AVERAGE CARBON DIOXIDE EVOLUTION AS A FUNCTION OF BATTERY TEMPERATURE DURING A THREE-HOUR CHARGE Conditions: 3M ZnCl + KC1 + NaCl 22 Charge: 3OmA/on Temperature Cell °C 3A 40 50 030 40 50 1A 30 40 50 Table 37-8 Average % CO2 in Chlorine Stream 0.08 0.15 0.03 0.07 0.12 0.02 0.04 0.13 HYDROGEN AND CARBON DIOXIDE EVOLUTION IN A ZINC-CHLORINE BATTERY AS A FUNCTION OF ELECTROLYTE pH Cell 0 Cell 1A pH=0.01 pH-0.0 %h2 %co2 ^2 Cell 3A pH=1.0 %h2 %co Time (hours) 0.5 1 *0.04 0.3 2 *0.03 0.2 4 0.03 0.04 0.1 6 0.1 0.06 0.1 0.1 0.5 0.3 0.04 0.7 0.2 0.02 0.5 0.4 0.03 2.9 0.8 0.03 run terminated * 0.05 0.6 *Hydrogen level too low for accurate measurement. 37-15

PDF Image | Development of the Zinc-Chlorine Battery for Utility

development-zinc-chlorine-battery-utility-222

PDF Search Title:

Development of the Zinc-Chlorine Battery for Utility

Original File Name Searched:

6302789.pdf

DIY PDF Search: Google It | Yahoo | Bing

Salgenx Redox Flow Battery Technology: Power up your energy storage game with Salgenx Salt Water Battery. With its advanced technology, the flow battery provides reliable, scalable, and sustainable energy storage for utility-scale projects. Upgrade to a Salgenx flow battery today and take control of your energy future.