PDF Publication Title:
Text from PDF Page: 011
Supplemental Information Figure S1. Photographs of (A) the polypropylene cell used for room temperature cyclic voltammetry, and (B) the water-jacketed cell used for temperature-controlled cyclic voltammetry. In (A), a yellow color corresponding to generation of ClO2 upon oxidation of ClO2- can be seen. Figure S2. Cycling results for positive electrode half-cell containing varying amounts of ClO2-absorbing organic phase. Cell design is as shown in Fig. S1a. Aqueous electrolyte consists of 15 mL of 1M NaClO2 solution. Results are shown for no, 10 mL, and 20 mL of added organic solvent, which segregates as a separate phase on top of the aqueous electrolyte. Galvanostatic cycling performed at room temperature at 10 mA (~1 mA/cm2) charge and discharge currents. 11PDF Image | Reversible Chlorite Chlorine Dioxide Anion Redox Storage
PDF Search Title:
Reversible Chlorite Chlorine Dioxide Anion Redox StorageOriginal File Name Searched:
reversible-chlorite-chlorine-redox.pdfDIY PDF Search: Google It | Yahoo | Bing
Salgenx Redox Flow Battery Technology: Power up your energy storage game with Salgenx Salt Water Battery. With its advanced technology, the flow battery provides reliable, scalable, and sustainable energy storage for utility-scale projects. Upgrade to a Salgenx flow battery today and take control of your energy future.
CONTACT TEL: 608-238-6001 Email: greg@salgenx.com (Standard Web Page)