6 TROUBLESHOOTING Blank display Excess of chlorine in the water • Check if ON/OFF switch is illuminated. • Check the connection wire between display and motherboard. • Check fuse of the device 3.15 A – it could have tripped due to overload. • Check the power supply 110V/60Hz – 230V/50Hz. • If problem persists contact TECHNICAL SERVICE • Lower electrolysis cell intensity. • If your system includes automatic redoX control, check redoX setpoint. • Check redoX probe and calibrate it if necessary. Electrolysis does not reach maximum intensity Titanium cell incrusted in less than 1 month • Low water temperature. • Check sodium bromide or common salt concentration in water. • Check cell status (may be incrusted or calcified). • Clean the cell according to the instructions in section 5. • Clean the flow detector situated in the cell housing. • Check titanium cell is not worn out (remember that the cell is guaranteed for 5.000 hours, approx. 2-3 years of summer usage). • Very hard waters with a high pH and total alkalinity: balance water adjusting pH and total alkalinity. • Check to ensure the system automatically changes polarity every 300 minutes approximately. • Consult with our technical service to consider accelerating the polarity change (auto-cleaning). WARNING: Accelerating the polarity change decreases the cell life (5.000 hours) proportionally. Free chlorine levels don’t reach 0,2 ppm Alarm AL3 and pH dosing pump stopped • Increase filtration interval. • Increase electrolysis level. • Check levels of sodium bromide or common salt in the pool (5 gr NaCl/l). • Check level of isocyanuric acid in pool (30-50 ppm), only if using common salt. • Check if reactive agents in test kit are expired. • Check if the temperature or amount of users has risen. • If the water pH is above 7,8 it must be adjusted. • The maximum dosing time (standard 200 min.) is accomplished and the acid dosing pump stops in order to avoid the acidification of the water. • To delete the message and to restart the metering press ESC ( ). Do the following verifications in order to preclude errors on the device: Verify if the pH probe reading is correct (if not, calibrate the probe or substitute it with a new one); Verify if the acid/base deposit is full and if the dosing pump is working correctly; Verify the variable speed of the dosing pump. Electrolysis display shows LOW White flakes in the water • Water lacks conductivity (see section 3 - Initial water adjustments). • Check for incrustations on cell. • See section 6 - Electrolysis does not reach maximum intensity. • The water is excessively hard and it is unbalanced. • Balance the water and check the cell, proceeding to clean it if necessary. • Put 1 small bag of flocculant in the skimmer and recirculate 24 hours. Electrolysis display shows FLOW Rust on metallic components in the pool • Check flow detector cable. • Clean incrustations of flow detector at the top of cell housing. • Check if system is free of air (probe must be always submerged). • Metallic elements lack standardized earth connection. Contact an electrician to solve the problem. • Rusted components are not stainless steel (minimum 304 – recommended 316). Polarity 1 reaches maximum intensity, but polarity 2 (auto clean) does not reach maximum intensity • If salt level is correct (5 kg/m3): Cell is reaching its end of life. As of this moment check intensity every 15-30 days. • When polarity 2 does not reach medium intensity, we recommend substituting the cell for a new one if it happens during the summer period. If it happens during winter, change the cell before the next summer period. WARNING Keep chemical levels in pool as instructed in this manual. CLEANING FILTER Very Important: Make sure the cell is off while cleaning the filter. If the system controls the filtration pump, use the option “filter cleaning” of the programmed filtration mode. See section 5 – Filtration / Filter Cleaning of the General Installation Guide. VERY IMPORTANT Remember that the system needs some time to adapt to your pool and that you will have to increase chemical levels for the first 5 days. EARTHING All metallic components in the pool such as lamps, ladders, heat exchangers, drains or similar elements within 3 m from the pool (10 feet) must be connected to an earth below 37 Ohms. If using heat exchangers, we recommend them to be made of titanium. SECURITY To avoid accidents, children should not handle this product unless supervised by an adult. Children should be supervised at all times when in or near a spa, pool or jacuzzi. HANDLING AND DOSING DANGEROUS CHEMICALS Chemicals should be handled with extreme precaution. When preparing acid, always add acid to water, never add water to acid, because very dangerous gasses may be produced.PDF Image | SEA WATER Cu Ag ionization
PDF Search Title:
SEA WATER Cu Ag ionizationOriginal File Name Searched:
BIONET-ENG.pdfDIY PDF Search: Google It | Yahoo | Bing
Salgenx Redox Flow Battery Technology: Power up your energy storage game with Salgenx Salt Water Battery. With its advanced technology, the flow battery provides reliable, scalable, and sustainable energy storage for utility-scale projects. Upgrade to a Salgenx flow battery today and take control of your energy future.
CONTACT TEL: 608-238-6001 Email: greg@salgenx.com | RSS | AMP |