3.2.6 Results. Thecalibrationcurvesforthesetransducersareshown in Figures 25 and 26. Some hysteresis was noted; values given above are for decreasing pressure for low 02 and increasing pressure for overpressure. AutoStart-upSequence Conditions. Sequentialcommandsignalsweremonitoredasafunction oftime. Theunitstowhichthecommandsignalsweredirectedwere deactivated during this test. Data Recording Requirements. Log book entries were made of command signals vs time. No data sheets. Values and Tolerances. 0 - 60 sec. + 2 sec. total. Results. The auto startup sequence was verified to be within tolerances. Shutdown Signal Sources Conditions. Each shutdown signal was either stimulated or simulated and the command to shutdownwas monitored. Data Recording Requirements. Log book entries: Pass or fail for each safety sensor. No data sheets. 3.2.7 Values and Tolerances. range 0-34.5kN/m(0-5psig) accuracy setpoints + 0.34kN/m (+o.o05psi) 2 9.0kN/m (1.3psi)low02pressure 17.7 kN/m2 (2.57 psi) 02 overpressure 2 16.7 kN/m (2.42 psi) H2 overpressure Values and Tolerances. Overtemperature Overpressure (02) (H2) Lo 02 pressure Electrolyte volume (high and low) H incabinet 2 Loss of power warn 30 + 1.0°C shutdown 40 + 1.0°C 17.7 kN/m2 (2.57 psig) 16.7kN/m (2.42 psig) 2 9.0 kN/m (1.3 psig) 1.5 and 0.75 kN/m2 (6 and 3 "H2 0) 54 2 2

PDF Image | WATER ELECTROLYSIS SYSTEM REFURBISHMENT

water-electrolysis-system-refurbishment-065

PDF Search Title:

WATER ELECTROLYSIS SYSTEM REFURBISHMENT

Original File Name Searched:

19730006433.pdf

DIY PDF Search: Google It | Yahoo | Bing

Salgenx Redox Flow Battery Technology: Power up your energy storage game with Salgenx Salt Water Battery. With its advanced technology, the flow battery provides reliable, scalable, and sustainable energy storage for utility-scale projects. Upgrade to a Salgenx flow battery today and take control of your energy future.

CONTACT TEL: 608-238-6001 Email: greg@salgenx.com | RSS | AMP