PDF Publication Title:
Text from PDF Page: 170
ADJUSTABLE WEIR CHLORINE ELECTRODE CHLORINE CONTACT BLOCK (FRAME & MANIFOLD) THREADED HOLES FOR ELECTRICAL CONTACTS STAND PIPES GLASS VIEWING PORT ZINC ELECTRODE PLASTIC ELECTRODE FRAME (4 PLACES} PLASTIC SPACER Figure 34-2. Demountable-electrode test cell built specifically for evaluation of chlorine-electrode voltaic performance. Cell was designed for easy turn around, thereby facilitating testing. Improved current-density distribution is achieved by contacting the chlorine electrode along its entire periphery and by using a thick (1/2") zinc electrode. Standpipes are employed instead of flowing gas-vents; viewing port allows visual determination of gas-blockage. After assembly, cell is clamped together (arrangements not shown), and placed in suitably-sized glass battery jar which acts as electrolyte sump. 34-5 ELECTROLYTE SUPPLY TUBEPDF Image | Development of the Zinc-Chlorine Battery for Utility
PDF Search Title:
Development of the Zinc-Chlorine Battery for UtilityOriginal File Name Searched:
6302789.pdfDIY PDF Search: Google It | Yahoo | Bing
Salgenx Redox Flow Battery Technology: Power up your energy storage game with Salgenx Salt Water Battery. With its advanced technology, the flow battery provides reliable, scalable, and sustainable energy storage for utility-scale projects. Upgrade to a Salgenx flow battery today and take control of your energy future.