PDF Publication Title:
Text from PDF Page: 067
1977 1978 Figure 25-8. Showing the number of test cycles accumulated with the passage of time during Phase I testing of the 1.7kWh battery system. This also was an isolated failure whose cause was not discovered. Nine cycling days were lost (Figure 25-8) due to these failures. This 100 cycles took a little over two months to complete. An electrolyte change after 14 cycles (99-112) was required as the result of a fluid exchange between battery and store. Cycles 200-300 The average energy efficiency of these cycles was 64.7%. Standard deviation was 25-12PDF Image | Development of the Zinc-Chlorine Battery for Utility
PDF Search Title:
Development of the Zinc-Chlorine Battery for UtilityOriginal File Name Searched:
6302789.pdfDIY PDF Search: Google It | Yahoo | Bing
Salgenx Redox Flow Battery Technology: Power up your energy storage game with Salgenx Salt Water Battery. With its advanced technology, the flow battery provides reliable, scalable, and sustainable energy storage for utility-scale projects. Upgrade to a Salgenx flow battery today and take control of your energy future.
CONTACT TEL: 608-238-6001 Email: greg@salgenx.com (Standard Web Page)