Development of the Zinc-Chlorine Battery for Utility

PDF Publication Title:

Development of the Zinc-Chlorine Battery for Utility ( development-zinc-chlorine-battery-utility )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 172

Figure 34-4. Photograph of assembled 0.83kWh zinc and chlorine buses. End combs from an 8.3kWh submodule have been utilized. The meshed combs (with necessary masking) were encased in a Kynar tray for the test unit. Inter-electrode gap is 80mls. TEMPERATURE CONTROLLER i----l-ocal-----1 -- CELL SUMP ELECTRIC HEATER THERMOCOUPLE CHLORINE SUPPLY Figure 34-5. battery unit. systems. Chlorination on discharge is accomplished by feeding gas to the electrolyte pump inlet. Temperature is controlled in the electrolyte loop proper, and not in a bypass line as with the small-cell study. ELECTROLYTE PUMP Operational system utilized in evaluation of scaled-up 0.83kWh Loop used is similar to that employed with some large battery 34-7

PDF Image | Development of the Zinc-Chlorine Battery for Utility

development-zinc-chlorine-battery-utility-172

PDF Search Title:

Development of the Zinc-Chlorine Battery for Utility

Original File Name Searched:

6302789.pdf

DIY PDF Search: Google It | Yahoo | Bing

Salgenx Redox Flow Battery Technology: Power up your energy storage game with Salgenx Salt Water Battery. With its advanced technology, the flow battery provides reliable, scalable, and sustainable energy storage for utility-scale projects. Upgrade to a Salgenx flow battery today and take control of your energy future.

CONTACT TEL: 608-238-6001 Email: greg@salgenx.com (Standard Web Page)